Home/Blog/Metal Core LED Layout
Blog · Metal Core

Metal Core LED Layout: Thermal Pad and Isolation Rules

On an insulated metal substrate the aluminium is the spreader, not the bottleneck. The dielectric is the thinnest layer and the worst conductor on the stack, which makes pad area and isolation thickness the two decisions that actually set the junction temperature.

The dielectric sets the limit, not the aluminium

An insulated metal substrate is three thermal resistances in series: the dielectric, the aluminium core spreading heat sideways, and the interface where the plate meets its sink. The dielectric is both the thinnest layer and the worst conductor — 1 to 3 W/m·K on a standard grade, 8 to 12 on a ceramic-filled one — so its term governs the total. Upgrading the core does not fix a dielectric that is too thin or too weak, and it is the most common misreading of an aluminium board quote.

Layer What matters Typical value Condition
Dielectric Conductivity 1–3 W/m·K standard, 8–12 ceramic-filled Per grade
Dielectric Thickness 75–150 µm Isolation class and grade
Aluminium core Conductivity ≈130–170 W/m·K Alloy and temper, 25 °C
Aluminium core Thickness 0.5–1.2 mm Stiffness and spreading
Circuit copper Finished weight 1–3 oz String current per IPC-2152

Conductivity belongs to its layer and its condition. Whole-board thermal resistance depends on source area and geometry, so it is calculated per design rather than merged into one number for an aluminium board.

The thermal pad is an area decision

The one-dimensional term is thickness over conductivity times area. At 100 µm of a 2 W/m·K grade under a 10 cm² source that is about 0.050 °C/W; a 4 W/m·K grade halves it, and doubling the core thickness moves the total by a fraction. The lever is area and grade — the pad under the die is where the layout either helps or fights the substrate.

Two layout habits cost real degrees. The first is a thermal pad sized to the die footprint exactly, which gives the heat nowhere to spread before it has to cross the dielectric. The second is running signal traces through the pad area, which breaks the copper into islands and turns one spreader into several narrow ones. Copper under and around the die is cheap; the dielectric is what is being paid for.

On a single-sided substrate there is no plated through via into the core, so heat leaves by conduction through the dielectric rather than by a via farm. That is why the dielectric grade, not the copper weight, is the first thing to upgrade when a junction budget fails — and why a hole that has to pass through the aluminium needs an insulating sleeve rather than a plated wall.

Isolation is the same decision made twice

The dielectric also carries the isolation requirement, so thickness is chosen once and paid for on both sides of the decision: thinner is thermally better and electrically tighter, and the grade and the withstand voltage have to be settled together rather than in sequence. Withstand is verified by hi-pot at the class stated on the drawing, on the finished part rather than on a coupon.

Layout matters here because the dielectric is at its thinnest where copper runs close to a routed edge. A copper pour taken to within a few tenths of the profile leaves no margin at the exact place where the part is handled, and the failure shows up as a breakdown at the edge rather than under the die. Set an explicit copper-to-edge distance for the isolation class and keep it in the pour rules, not in a note.

The same logic applies between voltage domains on the plate. A mains-side string and a control-side string on one substrate need a documented separation, and the figure belongs on the drawing alongside the dielectric thickness — a layout that respects it by accident will not survive the next revision.

Copper weight follows four conditions, not an ounce rating

Current capacity is not a property of an ounce. Per IPC-2152, ampacity is read at a stated width, thickness, temperature rise and environment, then compared against what the string actually draws. On LED plates the more useful calculation is often voltage drop, because a strip that dims at the far end is a resistance problem rather than a thermal one.

Copper Drop per metre at 2.0 mm width Cross-section against 1 oz Where it fits
1 oz (35 µm) ≈0.246 Ω/m 1× Signals, low-current strings
2 oz (70 µm) ≈0.123 Ω/m 2× Main loops, metre-class strips
3 oz (105 µm) ≈0.082 Ω/m 3× High-current feeds, dense rails

Computed from copper resistivity at 20 °C at the stated width. At 2 A over a metre of 2 oz that is about 0.25 V one way — roughly 2% of a 12 V rail, and twice that once the return path is counted.

White mask, finish, and the sulfur problem

White solder mask does optical work in a lighting fixture, and it yellows under sustained heat. The aging condition — temperature and hours — belongs on the drawing rather than being assumed from a generic mask specification, because a mask that holds colour at 80 °C may not at 120 °C.

ENIG is the default finish for LED plates. Immersion silver is a cost-effective alternative with one boundary: in sulfur-bearing atmospheres silver tarnishes, so a sealed luminaire and an industrial installation do not get the same answer. That is an environment class on the drawing, not a purchasing preference.

Six lines make two quotes comparable

Two quotes for the same drawing can differ by a third on the strength of what was left unstated. The comparable set is six lines: core alloy and temper, dielectric grade and thickness, finished copper weight, surface finish, panel format and utilisation, and the flammability listing — verified on the dielectric recognition rather than assumed from the fact that the core is metal.

Each missing line is a question worth asking before the order rather than after first article: which alloy and temper, which dielectric grade and thickness, finished or base copper, which finish and why, how many pieces per panel at what border, and V-0 on which layer’s listing. When those six are answered, the spread between quotes narrows to process class rather than to specification.

FAQ

What comes up on LED substrate reviews.

Does a thicker aluminium core mean better cooling?

Mostly no. The stack is three resistances in series and the dielectric governs: about 0.050 °C/W at 100 µm and 2 W/m·K under a 10 cm² source, a figure that barely moves when the core thickness doubles. Core thickness buys stiffness and spreading on large plates; thermal upgrades start with the dielectric grade.

Is 1 oz copper enough for an LED plate?

It depends on four conditions rather than one number: width, thickness, temperature rise and environment. In practice 1 oz carries signal and low-current strings, while 0.5 W-class strips and above move to 2 oz, where the drop arithmetic — about 0.123 Ω/m at 2.0 mm — protects end-of-strip brightness.

Can the dielectric be made thinner to improve the thermal path?

Only as far as the isolation class allows. Thickness is chosen against the withstand voltage, so thinning it is an electrical decision before it is a thermal one. Where more thermal headroom is needed inside the same isolation class, the grade goes up rather than the thickness going down.

Why do quotes for the same LED plate differ so much?

Because the same drawing is not the same six lines. Alloy and temper, dielectric grade and thickness, finished copper weight, surface finish, panel utilisation and the flammability listing all move the price, and a 4 W/m·K dielectric is not the same purchase as a 1 W/m·K grade with the same thickness.

Can FR-4 be used for an LED panel instead?

Inside its band, yes. FR-4 conducts at about 0.2 to 0.3 W/m·K against 1 to 3 for a standard metal-core dielectric, which clears the junction budget for sparse indicator panels under roughly 1 W/cm². If the calculation only passes at 25 °C ambient, the answer is the metal-core plate, not the cheaper laminate.

Related reading

Where this connects on the site.

Specifying an LED metal-core board?

Send the LED placement, the drive current and the isolation class. Quote in 24 hours, with the dielectric grade named. Every build runs to IPC Class 2 standard, Class 3 on request.